Send Email
 

PMA 4100 Series CALReady UVA and Photopic (Visible) Light Sensors

 

The PMA4100 Series CALReady Photostability sensors are process control sensors that have the capability of being calibrated in the field by the end user.

The PMA 4100-420 sensor System has two sensor types, the PMA 4110-420 UVA sensor and the PMA 4130-420 Photopic sensor.  The sensors detect light from their respective spectral bands and send a current proportioned signal on a 4 – 20 mA current loop.  The PMA 4110-420 sensor is sensitive to the 320 – 400 nm spectral band and has a maximum (20 mA) sensitivity of 1.000 W/cm².  The PMA 4130-420 sensor is sensitive to the CIE Weighted Photopic spectral range, 480 - 620 nm, and has a maximum (20 mA) sensitivity of 5000 Lux. 

This CALReadysensor system includes reference sensors, transfer calibrated from NIST traceable standards. One Reference sensor is available to calibrate the Process sensor for the Photopic range and one Reference sensor is available to calibrate the Process sensor for the UVA.  The software system can perform an in situ transfer calibration when connected via the USB.  

> Return to Detector Selection Guide

U.S.Pat.5,946,641

U.S.Pat.5,790,432

FEATURES

  • High sensitivity
  • Dynamic range 2*105
  • Excellent long term stability
  • Cosine corrected
  • NIST traceable calibration
  • Radiometric units and max. exposure time
  • Field Calibration

APPLICATIONS

SL3310 Calibration software

The unique feature of infield calibration is capable through use of the SL3301 software that can be installed on a laptop computer to meet performance standards.

      

 Photopic Sensor Specifications:

  • Spectral response: Follows CIE photopic spectral luminous efficiency curve (400-700nm) Figure 1
  • Angular response: 5% for angles <60°
  • Range:
    PMA2130 - 150,000 Lux, 220 W/m2, 14,000 ft-cd
    PMA2130L - 1,500 Lux, 2.2 W/m2, 140 ft-cd
    PMA2130H - 1,500,000 Lux, 2200 W/m2, 140,000 ft-cd
  • Display resolution:
    PMA2130 - 1 Lux, 0.001 W/m2, 0.1 ft-cd
    PMA2130L - 0.01 Lux, 0.00001 W/m2, 0.001ft-cd
    PMA2130H - 10 Lux, 0.01 W/m2, 1 ft-cd
  • Operating environment: 32 to 120 °F (0 to +50 °C) no precipitation
  • Cable:  5ft (1.5m)
  • Diameter: 1.6" (40.6 mm)
  • Height: 1.8" (45.8 mm)
  • Weight: 7.1 oz. (200 grams)

                                       Figure 1 - Photopic Spectral Response

 

UVA Sensor Specifications:

  • Spectral response: 320-400nm, figure 2
  • Angular response: 5% for angles <60°
  • Range: 200 [mW/cm2] or 2000 [W/m2]
  • Display resolution: 0.001 [mw/cm2], 0.01[W/m2]
  • Operating environment: 32 to 120 °F (0 to +50 °C) no precipitation
  • Temperature coefficient: <0.1%/°C
  • Cable:  5ft (1.5m)
  • Diameter: 1.6" (40.6 mm)
  • Height: 1.8" (45.8 mm)
  • Weight: 7.1 oz. (200 grams)

                                  Figure 2- UVA Spectral Response

> Return to Detector Selection Guide 

 